Page 14 WE 060517
Alarm e alarm symbol is shown when the unit encounters an issue that needs attention. e displayed alarm
codes are explained below. e alarm code will remain displayed until corrected.
Alarm Codes
CPSM (Customer Preference Selection Mode)
Message Cause Solution
E1 Faulty air-sensing probe
Contact Customer Service at 1-800-648-6058
AH1
e air probe is sensing a
temperature that is 10° above
the set point
1. Allow time for the wine to reach the desired temperature
2. Make sure all windows and doors are closed and have a proper seal
3. Follow the procedures in the pre-installation instructions to test the unit for proper
cooling
AL1
e air robe is sensing a
temperature that is 10° below
the set point
1. Make sure unit is not in cooling mode (the snowake symbol will not be lit)
2. Add heat to the room until the wine reaches the desired temperature
Press and hold the set button for approximately ve (5) seconds to enter the CPSM menu.
Use the DOWN ARROW button to access the following parameters.
PA2 No adjustable settings in this parameter.
tab No adjustable settings in this parameter.
Rel No adjustable settings in this parameter.
LOC Change this parameter from "n" to "y" to lock the keyboard from changes to the set point.
CA1 Change the value to increase or decrease the temperature reading of the air sensor. (is process recalibrates
the probe to the controller.) Increasing the value by 1 means an increase in the temperature reading by 1
degree. Decreasing the value by one means a decrease in the temperature reading by 1 degree. is param-
eter can be adjusted +- 12 degrees. If needed, adjust this setting to match the temperature sensor inside your
cellar.