Page 7www.wineenthusiast.com
Electrical Needs
e N'FINITY System requires a dedicated 115-volt, 20-amp circuit. e unit draws a large amount of amps at initial startup.
Match the electrical outlet to the plug provided on the N'FINITY unit and provide a dedicated circuit and wiring for the
unit. By designating a dedicated circuit breaker, you will guarantee the unit has enough power to run eectively. Contact an
electrician for assistance with the installation of this dedicated electrical circuit.
Electrical Outlet
Plug your N'FINITY unit into a surge protector or power conditioner. As with any sensitive electrical equipment, the
N'FINITY electrical equipment may be damaged by power surges and spikes. Power surges and spikes are not covered under
the N'FINITY warranty.
DO NOT USE A GROUND FAULT INTERRUPTER (GFI) WITH THIS PRODUCT.
Testing the Unit (prior to installation)
Carefully remove your N'FINITY unit from the box. Do not destroy your packaging material, as it provides the only safe
means of transporting the unit. Place the N'FINITY system on a tabletop to prepare it for installation and testing. Plug
system into a live electrical outlet and turn unit on. e system may take up to 10 to 15 minutes before operating correctly:
all four fans running, cold air issuing from the cellar side of the unit, and hot air coming out of the exhaust side. Once the
operation has been tested, turn the unit o and unplug it from the electrical outlet.
NOTE: If the system does not seem to be fully functional aer 15 minutes,
please refer to the Troubleshooting Guide on page 17.
Location of Supply and Return Grilles
Locate the supply and return grilles inside the cellar to create an airow pattern that maximizes air circulation in the room.
Avoid short circulation of the air.
DO NOT:
Install through-the-wall return air grilles at oor level, as they will collect dust from the oor.
Mount the unit more than 18 inches from the top of the room.
Locate the supply or return air grille where it is blocked by bottles, boxes or cases.
Units weigh 75-85 pounds and are cumbersome for one person to carry. We recommend that you get someone else to help
you during the installation process. NEVER LAY UNIT ON ITS SIDE.
PRE-INSTALLATION