28
Reset to default configuration
(continuous scanning
mode)
0.5s: 07 C6 04 08 00 89 05 FE 99
3s:07 C6 04 08 00 89 1E FE 80
End mark
Null :08 C6 04 08 00 F2 05 00 FE 2F
CRLF:08 C6 04 08 00 F2 05 01 FE 2E
Enter:08 C6 04 08 00 F2 05 02 FE 2D
TAB: 08 C6 04 08 00 F2 05 03 FE 2C
Turn on/Turn off
configuration code
Enable :07 C6 04 08 00 EC 01 FE 3A
Disable :07 C6 04 08 00 EC 00 FE 3B
Enable\Disable sending
setting code
Enable :08 C6 04 08 00 F1 71 01 FD C3
Disable :08 C6 04 08 00 F1 71 00 FD C4
Power mode
Continuous power mode:07 C6 04 08 00 80 00 FE A7
Power saving mode: 07 C6 04 08 00 80 01 FE A6
Re-scanning time (Auto
mode)
1500ms:08 C6 04 08 00 F3 03 0F FE 21
500ms:08 C6 04 08 00 F3 03 05 FE 2B
300ms: 08 C6 04 08 00 F3 03 03 FE 2D
Sensitivity setting
Special sensitivity:08 C6 04 08 00 F2 04 00 FE 30
High sensitivity:08 C6 04 08 00 F2 04 01 FE 2F
Middle sensitivity:08 C6 04 08 00 F2 04 02 FE 2E
Low sensitivity:08 C6 04 08 00 F2 04 03 FE 2D
3.2 Volume and light setting
function
Instructions(HEX )
Power indicator light
Decode on: 08 C6 04 08 00 F2 0A 00 FE 2A
Always on: 08 C6 04 08 00 F2 0A 01 FE 29