group are tripped within 2 minutes. This feature is designed to afford redundant protection for devices, such as glass break
detectors, PIR's, etc., that may show a tendency to false under certain conditions. Program each Group for any number of
Zones available. All Zones in any Group must be within the same area (partition) and not overlap to other areas. Do not mix
24-Hour Zones and non-24-Hour Zones within the same Group. Do not include a Panic Zone as part of any Group. Auto-
Reset must be programmed for each Zone ANDing Zone. Note: Any zone that is bypassed or goes into Swinger Shutdown
will automatically disable Zone Anding for the entire Group. If "Enable Local Alarm on First Zone AND Trip" is programmed, a
trip on any Zone of the Group will cause an alarm output and alarm display at the keypad; there will be no communication to
the central station. Note: If "Enable CP-01 Limits" is enabled in EZ Programming, any Zone in a Group will only activate an
alarm and send a report ONCE. After the Zone has reported, it will remain in the Group and may still initiate the Zone ANDing
sequence.
Zone Area 1–Zone Area 8 See Areas
Zone Type See Receiver Format