NAPCO Gemini C-Series Control Panel Programming Instructions--Volume 2
NAPCO Security Group
Programming Instructions, Volume 2 Page 101
SYSTEM OPTIONS (ADDRESS 5328-5329)
SYSTEM OPTIONS:
1. Select System Options from the tables shown and enter in the corresponding address location at right.
2. Press U to save. NOTE: Dark shaded data value box shows option not available.
*Note: Address 5328 Option 8 Keypad Blanking clears all data from the LCD display (and turns off all keypad LED's) after the
system is armed and delay time has expired. The display will re-appear when an exit/entry door is faulted, causing an entry time
delay display, or if a valid user code is entered at the keypad while the system is armed.
ADDRESS 5328
SYSTEM OPTIONS
DATA ENTRIES
RIGHT
OPTION
1 Enable ACM Access
2 Access Log to 6000 Events
3 Enable TCP/IP Communications
4 TCP/IP Panel/Site Initiated Functions
5 Disable H/A Keypad Display
6 RESERVED
7 Enable EURO Features
8 Enable Keypad Blanking*
ADDRESS 5329
SYSTEM OPTIONS
DATA
ENTRIES
RIGHT
OPTION
1 Enable Burg Module On System
2 Enable GEMC-F8ZCPIM
3 Enable Housing Tamper
4 Coded Alarms By Zone
5
ENABLE BURG POINT REPORT TAMPER ON (RF-XMIT
PNT/BSLC PNT TAMPER) ONLY IF ZONE ARMED
6
ENABLE RF RECEIVER OR BURG RF TRANSMITTER OR
SLC TAMPER TO SOUND BURG ALARM ONLY IF ANY
AREA ARMED
7 RESERVED
8 RESERVED