SLE Series Alarm Communicators -- Installation Instructions 15
Wiring Diagram for BACKUP Reporting Configuration
GEM-X255 / GEM-P9600 / GEM-P3200 Control Panels
(+) (–)
AUX POWER
GRN
RED
BRN
GRAY
(CONTROL PANEL HOUSING)
1
2
3
4
5
6
7
8
9
10
11
12
13 14 15 16 17 18 19 20 21 22 26 27 28 29 23 24 25 33 30 31 32
GRAY
BRN
BLACK
YELLOW
Control Panel PC Board
16VAC
*For StarLink module
terminals 1 and 2:
May be wired directly
to Aux Power of the
control panel when
65mA standby cur-
rent is available.
TIP RING TIP RING
TEL LINE PHONE
HOME
PHONES
TO TELCO
RJ31X
Summary of connections:
 RJ31X RED to StarLink module 10
 RJ31X GREEN to StarLink module 11
 RJ31X BROWN to Panel 32
 RJ31X GRAY to Panel 33
 Panel 30 to StarLink module 13
 Panel 31 to StarLink module 12
GRN
RED
GRN
RED
RING TIP
GRN
RED
YELLOW
BLACK
*Refer to section "SUPPLYING POWER".
6 7 8 15 14 13 12 11 9 10 2* 3 4 5 1*
+12V
()
PGM1 PGM2 PGM3 IN1 IN2 GND IN3 RING TIP
17 16
RTS
(R)
PANEL
TX (B)
PANEL
RX (G)
CTS
Y
StarLink Radio Terminals
PANEL
RING (+)
PANEL
TIP (–)
(STARLINK RADIO HOUSING)
Optional: When Power Supply
SLE-SMTCHG is not used,
connect Panel Aux Power to
StarLink terminals 1 and 2
(observing polarity)
16VAC
Transformer
TELCO QUAD WIRE
J600
A
B
Jumper (J600)
(located only on
models SLE-CDMA-
8D and SLE-GSM-
8D-3/4G) must be
placed on "A" (top
two pins) to enable
remote downloading.