Pilot goes out while
standing; Main
burner is in 'OFF'
position.
Gas piping is undersized.
- turn on all gas appliances and see if pilot flame flutters, dimin-
ishes or extinguishes, especially when main burner ignites. Moni-
tor appliance supply working pressure.
- check if supply piping size is to code. Correct all undersized
piping.
Pilot goes out when
the gas knob is re-
leased.
The gas valve has
an interlock device
which will not allow
the pilot burner to
be lit until the ther-
mocouple has
cooled. Allow ap-
proximately 60
seconds for the
thermocouple to
cool.
System is not correctly
purged.
- purge the gas line with the glass door removed.
Out of propane gas.
- fill the tank.
Pilot flame is not large
enough
- turn up the pilot flame.
- gently twist the pilot head to improve the flame pattern around the
thermocouple.
Pilot flame is not engulfing
the thermocouple.
Thermocouple shorting /
faulty.
- loosen and tighten thermocouple.
- clean thermocouple and valve connection.
- replace thermocouple.
- replace valve.
Faulty valve.
- replace.
Pilot burning; no
gas to main
burner; gas knob
is on 'HI'; wall
switch / thermostat
is on.
Themostat or switch is de-
fective.
- connect a jumper wire across the wall switch terminals; if main
burner lights, replace switch / thermostat.
Main burner orifice is
plugged.
- remove stoppage in orifice.
Faulty valve.
- replace.
Wall switch wiring is de-
fective.
- disconnect switch wires from valve & connect a jumper wire across
terminals 1 & 3; if the main burner lights, check the wires for de-
fects and / or replace wires.
Pilot will not light.
- check if pilot can be lit by a match
- check that the wire is connected to the push button ignitor.
- check if the push button ignitor needs tightening.
- replace the wire if the wire insulation is broken or frayed.
- replace the electrode if the ceramic insulator is cracked or broken.
- replace the push button ignitor.
No spark at pilot burner
- fill the tank.Out of propane gas
Spark gap is incorrect
- spark gap should be 0.150" to 0.175" (5/32" to 11/64" approx.)
from the electrode tip and the pilot burner. To ensure proper elec-
trode location, tighten securing nut (finger tight plus 1/4 turn).
No gas at the pilot burner
- check that the manual valve is turned on.
- check the pilot orifice for blockage.
- replace the valve.
- call the gas distributor.
Main burner goes
out; pilot stays on.
Pilot flame is not large
enough or not engulfing
the thermopile
- turn up pilot flame.
- replace pilot assembly.
Thermopile shorting
- clean thermopile connection to the valve. Reconnect.
- replace thermopile / valve.
Remote wall switch wire
is too long; too much re-
sistance in the system.
- shorten wire to correct length or wire gauge.
Faulty thermostat or
switch.
- replace.
TROUBLE SHOOTING GUIDE
B
EFORE
ATTEMPTING
TO
TROUBLESHOOT
,
PURGE
YOUR
UNIT
AND
INITIALLY
LIGHT
THE
PILOT
AND
THE
MAIN
BURNER
WITH
THE
GLASS
DOOR
REMOVED
.
SYMPTOM PROBLEM TEST SOLUTION