© National Instruments Corporation 13 BNC-2111 Installation Guide
Voltage
Refer to the device specifications for the voltage rating for your
DAQ device.
Maximum voltage .................................. 42 V
Physical
Dimensions
With metal enclosure ...................... 19.05 by 10.48 by 3.51 cm
(7.5 by 4.125 by 1.38 in.)
Without metal enclosure
(board only)..................................... 18.796 by 8.89 by 5.034 cm
(7.4 by 3.5 by 1.982 in.)
I/O connector.......................................... 68-pin male connector
BNC connectors ..................................... 24
Environment
Operating temperature............................ 0 to 55 °C
Storage temperature ............................... –55 to 125 °C
Relative humidity ................................... 5 to 90%, noncondensing
Altitude................................................... 2,000 m
Pollution Degree .................................... 2 (Indoor use only)
Safety
The BNC-2111 meets the requirements of the following standards for
safety and electrical equipment for measurement, control, and
laboratory use:
• IEC 61010-1, EN 61010-1
• UL 61010-1
• CAN/CSA-C22.2 No. 61010-1
Note For UL and other safety certifications, refer to the product label, or visit
ni.com/certification, search by model number or product line, and click the
appropriate link in the Certification column.