NI 9411 Operating Instructions and Specifications 18 ni.com
Power Requirements
Power consumption from chassis
Active mode ............................... 340 mW max
Sleep mode .................................1.1 mW max
Thermal dissipation (at 70 °C)
Active mode ............................... 1.4 W max
Sleep mode .................................1.1 W max
External Power Supply
Input voltage range (V
sup
)................. 5 to 30 VDC max
5V regulated output
Voltage tolerance ........................5 V 3%, V
sup
6V
Current........................................200 mA
Short-circuit protection .............. 400 mA
Note The NI 9411 does not provide overvoltage
protection.