For information about connecting counter signals, refer to the
Default Counter/Timer Pinouts
section.
Counter Output Applications
The following sections list the various counter output applications available on M series devices:
Simple Pulse Generation
Pulse Train Generation
Frequency Generation
Frequency Division
Pulse Generation for ETS
Simple Pulse Generation
Refer to the following sections for more information about the M Series simple pulse generation
options:
Single Pulse Generation
Single Pulse Generation with Start Trigger
Retriggerable Single Pulse Generation
Single Pulse Generation
The counter can output a single pulse. The pulse appears on the Counter n Internal Output signal
of the counter.
You can specify a delay from when the counter is armed to the beginning of the pulse. The delay
is measured in terms of a number of active edges of the Source input.
You can specify a pulse width. The pulse width is also measured in terms of a number of active
edges of the Source input. You also can specify the active edge of the Source input (rising or
falling).
Figure 7-22 shows a generation of a pulse with a pulse delay of four and a pulse width of three
(using the rising edge of Source).
Figure 7-22. Single Pulse Generation
SOURCE
OUT
Counter Armed