© National Instruments 37 NI sbRIO-960x/962x/963x OEM Instructions & Specifications
.
Figure 30. NI sbRIO Device Power Connector
3. Connect the C lead of the power supply to position 2 of the 2-position
power connector plug.
4. Insert the power connector plug into the power connector receptacle of
the NI sbRIO device until the connector latches into place.
5. Turn on the power supply.
Powering On the NI sbRIO Device
The NI sbRIO device runs a power-on self test (POST) when you apply
power to the device. During the POST, the Power and Status LEDs turn on.
When the Status LED turns off, the POST is complete. If the LEDs do not
behave in this way when the system powers on, refer to the Understanding
LED Indications section.
Device Startup Options
You can configure the following device startup options in NI Measurement
& Automation Explorer (MAX):
• Safe Mode
•Console Out
•IP Reset
•No App
•No FPGA App
To turn these startup options on or off, select the controller under Remote
Systems in the MAX configuration tree, then select the Controller
Settings tab. Refer to the MAX Help for information about the startup
options and how to configure the controller.
1 V Terminal 2 C Terminal