NI sbRIO-960x/962x/963x OEM Instructions & Specifications 58 ni.com
Component Maximum Case Temperature
Note Some systems may require a heat sink or air flow to remain within the maximum
allowed temperature ranges. A heat spreader is available from National Instruments that
you can mount on the NI sbRIO device. The heat spreader is NI 9695, part number
153901-01.
Note For information about and examples of environmental and design factors that can
affect the thermal performance of NI sbRIO systems, so to
ni.com/info and enter the
Info Code
sbriocooling.
Storage temperature
(IEC 60068-2-1, IEC 60068-2-2) ...........–40 to 85 °C
Operating humidity
(IEC 60068-2-56) ...................................10 to 90% RH, noncondensing
Storage humidity
(IEC 60068-2-56) ...................................5 to 95% RH, noncondensing
Maximum altitude...................................5,000 m
Pollution Degree (IEC 60664)................2
Physical Characteristics
Weight
NI sbRIO-9605 ................................85 g (2.998 oz)
NI sbRIO-9606 ................................89 g (3.139 oz)
NI sbRIO-9623 ................................123 g (4.24 oz)
NI sbRIO-9626 ................................133 g (4.69 oz)
NI sbRIO-9633 ................................131 g (4.62 oz)
NI sbRIO-9636 ................................132 g (4.66 oz)
Table 14. Component Maximum Case Temperature
Component
*
Manufacturer Max Case Temp.
FPGA Xilinx 93 °C
Processor Freescale 107 °C
DDR memory Micron 97 °C
NAND flash Micron 90 °C
*
Refer to Figure 2 for component locations