SCXI-1353 Shielded Cable Assembly 10 ni.com
You can connect the EXTENDED I/O cable, using the AI-48/DIO-24,
to the SCXI-1180 feedthrough panel or SCXI-1181 module.
Using the SCXI-1353 with an NI 6021E or NI 6025E
The MIO-16 cable connects the MIO-16 portion of the AT-MIO-16DE-10
pinout to the SCXI-1349. The EXTENDED I/O cable connects the
remainder of the AT-MIO-16DE-10 pinout to the AI-48/DIO-24.
You can connect the MIO-16 cable, using the SCXI-1349, to the following
SCXI modules: SCXI-1100, SCXI-1120, SCXI-1121, SCXI-1122,
SCXI-1124, SCXI-1140, SCXI-1141, SCXI-1160, SCXI-1161,
SCXI-1162, SCXI-1162HV, SCXI-1163, SCXI-1163R, SCXI-1180,
or SCXI-1181.
You can connect the EXTENDED I/O cable, using the AI-48/DIO-24,
to the following SCXI modules: SCXI-1162, SCXI-1162HV, SCXI-1163,
SCXI-1163R, SCXI-1180 feedthrough panel, or SCXI-1181.
Note If the module that you are using is not listed here, please refer to the NI Web site
at
ni.com/support for technical support.
Specifications
Maximum Working Voltage
Maximum working voltage refers to the signal voltage plus the
common-mode voltage.
Channel-to-earth .....................................±15 V, installation category I
Channel-to-channel.................................±15 V, installation category I
Environmental
Operating temperature ............................0 to 50 °C
Storage temperature................................–20 to 70 °C
Humidity.................................................10 to 90% RH, noncondensing
Maximum altitude...................................2000 meters
Pollution degree (indoor use only) .........2