2
™
1. With the Console activated and in Power-Up mode, push the
START/ENTER button.
2. Within 5 seconds of completing Step 1, push and hold down the
Reset and Increase buttons for 3 seconds. The Console is now in
Service Mode.
3. Now push and hold down the Reset and Increase buttons again
for 3 seconds. The Console is now in the Calibrate the Magnetic
Resistance Sensor option (display with placeholders shown).
4. The Console displays four values with one of them ashing.
Note: The Magnetic Resistance Sensor can only be calibrated three
times. If the Console displays the Calibration Round as “3”, then it
cannot be calibrated again.
The upper value is the current position supplied by the Resistance
Knob. This is the value controlled by the user.
The 1% Congured Value is the previously calibrated position for the
1% Resistance Value. This value is the rst to be calibrated and is the
one ashing.
Turn the Resistance Knob counter-clockwise until it is unable to turn,
and then turn it clockwise a quarter of a turn.
5. Push the START/ENTER button to set this value as the new 1%
Congured Value. The Console will update the displayed value.
6. The Console will now ash the 100% Congured Value. The 100%
Congured Value is the previously calibrated position for the 100%
Resistance Value.
With one hand on the front of the Flywheel, slightly turn the Flywheel
while turning the Resistance Knob clockwise. Immediately stop turning
the Resistance Knob when the Flywheel is unable to turn.
Be sure to keep ngers clear of all pinch hazards as you
slightly turn the Flywheel.
7. Turn the Resistance Knob counter-clockwise one full turn.
8. Conrm that the Flywheel can move by turning it. If the Flywheel
cannot turn, the Resistance Knob has been turned too far. Go back to
Step 6.
START/
ENTER
button
Reset button
Increase button
Resistance Knob
Current position
value
1% Congured
Value
100% Congured
Value
Calibration
Round
Flywheel