22 Troubleshooting
5.2 Understanding Error Codes
When an error code appears on the front panel, refer to the following chart for a definition and possible remedy for the situation.
Error Code Reason Self-diagnostic / Action
E003 Ignition failure Ensure that the main gas supply valve is open.
E004 False flame detection Ensure that the electrical cord is properly grounded.
E012 Flame loss
Clean the intake air filter.
Ensure that the electrical cord is properly grounded.
E016 Overheating of heat exchanger
Turn off the system for at least 30 minutes, and then restart it.
Clean the Heating Return filter.
Flush the heat exchanger.
E030 Abnormal exhaust temperature Contact Technical Support at 1-800-519-8794.
E046 Abnormal operation: limit control Contact Technical Support at 1-800-519-8794.
E047 Abnormal operation: exhaust thermostat Contact Technical Support at 1-800-519-8794.
E060 Abnormal operation: dual venturi Contact Technical Support at 1-800-519-8794.
E109 Abnormal operation: fan motor Clean the intake air filter.
E110 Abnormal air pressure
Ensure that the exhaust pipe is free of obstructions.
Clean the intake air filter.
E205 Heating supply thermistor open or short circuit Contact Technical Support at 1-800-519-8794.
E218 Heating return thermistor open or short circuit Contact Technical Support at 1-800-519-8794.
E351 Abnormal Auto feeder valve (make-up water) Contact Technical Support at 1-800-519-8794.
E352 High water pressure Contact Technical Support at 1-800-519-8794.
E353 Abnormal operation: water pressure sensor Contact Technical Support at 1-800-519-8794.
E407 Hot water outlet thermistor open or short circuit Contact Technical Support at 1-800-519-8794.
E421 Cold water inlet thermistor open or short circuit Contact Technical Support at 1-800-519-8794.
E515 Abnormal operation: PCB
Ensure that the electrical cord is properly grounded.
Reset the boiler from the front panel.
E517 Abnormal operation: DIP switch setting Contact Technical Support at 1-800-519-8794.
E594 Abnormal operation: EEPROM Contact Technical Support at 1-800-519-8794.
E615 Abnormal operation: input and memory Contact Technical Support at 1-800-519-8794.
E740
Abnormal operation: outdoor temperature
sensor (appears only when the outdoor reset
curve is enabled).
Ensure that the outdoor reset curve is configured properly.
Check the outdoor temperature sensor wiring connection.
E777 Abnormal operation: LWCO
Check the LWCO wiring connection
Ensure that the system water level is appropriate.
Add make-up water to the system if necessary.
E782 Abnormal operation: main panel communication Contact Technical Support at 1-800-519-8794.
If any of these remedies do not resolve the problem, contact Technical Support at 1-800-519-8794.