©Navien America Inc. 2010 NR/NP series service Manual
67
Version 2.0
5.3. 03Error
Error occurrence conditions and check items
DescriptionError
03E
Ignition fail
Check items
In case of an ignition fail, repeat restart 10 times. If no ame is detected, the system
displays the error message 03E (manually cleared) on the remote controller.
Check the gas supply (check
the gas valve and supply pressure).
Check the operation of the ignition transformer (ignition state, input power
(AC 102~132 V))
Check the operation of the gas control valve (DC 83~120 V, coil short
circuit,
solenoid valve).
Check theame detecting rod, and wiring and grounding.
Check if the air pressure hose is broken or clogged.
Check if the air pressure sensor works proper
ly.
Check the PCB DIP S/W capacity setting.
Adjust dierential pressure to MIN between 3 stages with the gas detector.
Disassemble the manifold and check the nozzle.
Check theue and air supply (downw
ard installation / rainwater collected)
If the trouble continues despite the checking of above items, replace the PCB.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.

Table of Contents

Other manuals for Navien NR-180

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Navien NR-180 and is the answer not in the manual?

Navien NR-180 Specifications

General IconGeneral
CategoryTankless Water Heater
TypeCondensing
Fuel TypeNatural Gas or Propane
Max. Output BTU180, 000 BTU/h
Energy Factor (EF)0.96
Water Connection3/4" NPT
Gas Connection3/4" NPT
Heat ExchangerStainless Steel
Electrical Requirements120V, 60Hz
Efficiency96%
Venting2" PVC/CPVC or 3" Concentric