3 - 20 Equipment
___________________________________________________________________________________
___________________________________________________________________________________
Document Revision 4 Electra Elite IPK
Table 3-5 KSU Power-Based ETU Quantity Limitations for Systems with
EliteMail VP/CTI or CTI ETU loaded with Q-Master Application
Number of
ESI(8) ETUs
,
Number of
ESI Ports
Either
EliteMail VP/
CTI
Maximum NO. of
ACD+/CMS/FMS/
VMS/VMP/IPC/MG/
IVR/IPT/IAD/SLI/
OPX/BSU(4M)/
BSU(2S)/BSU(6S)
or DID ETUs
Other ETUs
9 72 1 0 No Limitation
8 64 1 0 No Limitation
7 56 1 1 No Limitation
6 48 1 2 No Limitation
5 40 1 2 No Limitation
4 32 1 3 No Limitation
3 24 1 4 No Limitation
2 16 1 4 No Limitation
1 8 1 5 No Limitation
,
The number of 8-port ESI ETUs installed including ESI(8)-U( ) ESIB(8)-U( ) ETU, or
ESIE(8)-U( ) ETU.
When the SPE(M)-U( ) ETU or MIFM-U20 with Ethernet option installed in the AP slot, the
HUB or EliteMail CTI/VP ETU must be installed in a different cabinet.
Only one CTI ETU can be installed in a KSU (EliteMail, VP, or Q-Master).