5 - 6 Hardware Specifications
___________________________________________________________________________________
___________________________________________________________________________________
Document Revision 4 Electra Elite IPK
SECTION 4 POWER REQUIREMENTS
4.1 Power Supply Inputs
The AC input (P64-U( ) PSU) requirements for the Electra Elite IPK are listed
below:
AC input (P64-U( ) PSU)
H
117 Vac ± 10%
H
60 Hz ± 10%
H
Single Phase
H
7.5A circuit
H
A dedicated outlet, separately fused and grounded, is required.
4.2 Power Supply Consumption
The power consumption for the Electra Elite IPK system is listed in the table
below.
SECTION 5 ENVIRONMENTAL CONDITIONS
5.1 Temperature
H
Operating: +32°F ~ +104°F (0°C ~ 40°C)
H
Recommended Long Term: +50°F ~ +90°F (10°C ~ 32.2°C)
5.2 Humidity
H
Operating: 10% ~ 90% noncondensing
Table 5-6 Power Consumption
KSU
Maximum
RMS
Current
Watts Used
(Idle)
Watts Used
(Maximum)
Basic KSU – B64-U( ) KSU 2.5 A 120 230
Basic KSU + Expansion KSU 5.0 A 240 460
Basic KSU + 2 Expansion KSUs 7.5 A 360 690