Chapter 5 Station Equipment
Page 5- 28 NEAX2000 IPS
Request For Proposal (RFP) Reference Guide
NDA-24349 Issue 4
D
term
Series E Line Conditions
Loop Resistance and Distance (Long Loop circuit built-in)
Terminal
Maximum
Loop Resistance ()
Cable Length
(24 AWG Cable)
(Without
ACA Unit)
Cable Length
(24 AWG Cable)
(With ACA Unit)
DTP-8-1 TEL 35 1000 ft. (304 m) 4000 ft. (1219 m)
DTP-8D-1 TEL 35 1000 ft. (304 m) 4000 ft. (1219 m)
DTP-16D-1 TEL 26 650 ft. (198 m) 4000 ft. (1219 m)
DTP-32D-1 TEL 21 650 ft. (198 m) 4000 ft. (1219 m)
4DLC
DCU-60-1 Console N/A N/A 1000 ft. (304 m)
DTP-8-1 TEL 35 1000 ft. (304 m) 1000 ft. (304 m)
DTP-8D-1 TEL 35 1000 ft. (304 m) 1000 ft. (304 m)
DTP-16D-1 TEL 26 650 ft. (198 m) 1000 ft. (304 m)
DTP-32D-1 TEL 21 650 ft. (198 m) 1000 ft. (304 m)
8DLC
DCU-60-1 Console N/A N/A 1000 ft. (304 m)
DTP-8-1 TEL 35 2800 ft. (853 m) 4000 ft. (1219 m)
DTP-8D-1 TEL 35 2800 ft. (853 m) 4000 ft. (1219 m)
DTP-16D-1 TEL 26 2800 ft. (853 m) 4000 ft. (1219 m)
DTP-32D-1 TEL 21 2800 ft. (853 m) 4000 ft. (1219 m)
2DLCB/N