Chapter 10 System Input/Output (I/O) Interfaces
NEAX 2000 IPS
Request for Proposal (RFP) Reference Guide Page 10-3
NDA-24349, Issue 4
MP built-in SMDR on IP
ITEM Specifications
Physical Layer
Ethernet
Connection Layer
The Ethernet packet format complies with the DIX standard
TCP/IP Protocol
ARP, IP, ICMP, UDP, TCP
Socket Interface
Complies with 4.3 BSD socket interface
Transport Protocol TCP stream type protocol
Application Port Number 60010 (fixed)
Number of Connections 1
Client/Server Client: SMDR terminal
Server: PBX
Transmission Code 7-bit ASCII code
Quasi-normal Restriction Condition 1. When conection is closed
2. Status monitoring text
Note 1: The MP card in main site communicates with the SMDR terminal. Therefore, in the communication
settings at SMDR terminal side, set the IP address to connected to the address specified by office data
(CM0B Y=00>00 or CM0B Y=02>03), and application port number shown in the above table.
Note 2:
One message is sent each time a request is received from SMDR terminal.
Combinations between SMDR and SMDR Output Format
SMDR
Former
NEAX 2400 IMS
Format
Extended
NEAX 2400 IMS
Format
NEAX 2000
Format
SMDR with AP00
(PN-AP00-B with AP00 program)
X — X
SMDR with AP00
(PN-AP00-B with MRCA program
)
X
X
NOTE
—
MP built-in SMDR on RS-232C
X X —
MP built-in SMDR on IP
X X —
X: Available —: Not available
Note: The extended NEAX 2400 IMS format is available by using SC-3168 MRCA program issue 2 or later.
Combinations available at the same time
SMDR Pattern A Pattern B Pattern C
Pattern D
SMDR with AP00
(PN-AP00-B with AP00 program)
X — X —
SMDR with AP00
(PN-AP00-B with MRCA program
)
— X — X
MP built-in SMDR on RS-232C
X X — —
MP built-in SMDR on IP
— — X X
X: Available —: Not available