ND-70373 (E) CHAPTER 2
Page 9
Revision 1.0
INSTALLATION PROCEDURE
Table 2-1 Cable Connections for IMG
x
[1]~[5] : For system 0
[6]~[10] : For system 1
NO.
CABLE CONNECTION
CABLE NAME REMARKS
FROM TO
MODULE
/UNIT
CIRCUIT
CARD
CONNECTOR
MODULE
/UNIT
CIRCUIT
CARD
CONNECTOR
[1] SN1433 CPRAF-A
(Front)
PZ-GT17 BUS CNB
(SLOT No.6)
PIM0 - BUS0A 50-40 GT BUS
CA-A
[2] SN1433 CPRAF-A
(Front)
PZ-GT17 BUS CNA
(SLOT No.6)
LPR BZ-C10 BUS0 EXGT BUS CA-A
[3] SN1433 CPRAF-A
(Front)
PZ-PW92 IN PWR BASEU PZ-M371 PA0 4P-2P PWR CA-A
[4] SN1433 CPRAF-A
(Front)
PZ-PW92 OUT PWR LPR BZ-C10 PWRA0 6P-(4P-3P) PWR
CA-A
PWRB0
[5] SN1433 CPRAF-A
(Front)
PZ-PW92 PALM LPR BZ-C10 PALM0 10AL-(110) FLT
CA
[6] SN1433 CPRAF-A
(Front)
PZ-GT17 BUS CNB
(SLOT No.6)
PIM0 - BUS1A 50-40 GT BUS
CA-A
[7] SN1433 CPRAF-A
(Front)
PZ-GT17 BUS CNA
(SLOT No.6)
LPR BZ-C10 BUS1 EXGT BUS CA-A
[8] SN1433 CPRAF-A
(Front)
PZ-PW92 IN PWR BASEU PZ-M371 PB0 4P-2P PWR CA-B
[9] SN1433 CPRAF-A
(Front)
PZ-PW92 OUT PWR LPR BZ-C10 PWRA1 6P-(4P-3P) PWR
CA-B
PWRB1
[10] SN1433 CPRAF-A
(Front)
PZ-PW92 PALM LPR BZ-C10 PALM1 10AL-(130) FLT
CA