DUAL HOLD-D
term
– 247 –
A2247-10
DUAL HOLD-D
term
PROGRAMMING
HARDWARE REQUIRED
D
term
and DLC card
DESCRIPTION DATA
Assign the Service Restriction Class B for
this feature to required stations.
(1)
(2)
Y=02
X-XXXXXXXX: Station No.
XX ZZ
ZZ: 00-15 : Service Restriction Class
B
Allow Dual Hold in the Service Restriction
Class B assigned by CM12 Y=02.
(1)
(2)
Y=64
00-15: Service Restriction Class B as-
signed by CM12 Y=02
1 : Allow
CM15
START
END
CM12