AUTOMATIC HOLD-D
term
– 64 –
A2056-10
AUTOMATIC HOLD-D
term
PROGRAMMING
NOTE: An ANSWER key is initially assigned on each D
term
.
HARDWARE REQUIRED
D
term
and DLC card
DESCRIPTION DATA
Assign the Service Restriction Class B for
Automatic Hold to the required D
term
.
(1)
(2)
Y=02
X-XXXXXXXX: My Line No.
XX ZZ
ZZ: 00-15 : Service Restriction Class
B
Allow Automatic Hold in the Service Re-
striction Class B assigned by CM12 Y=02.
(1)
(2)
Y=72
00-15: Service Restriction Class B as-
signed by CM12 Y=02
0: Allow
CM15
START
CM12
END