Issue 1.0 UNIVERGE SV8100
2 - 12 System Maintenance
Multiline Terminal Function Problems
No
No
No
No
No
Yes
Yes
Yes
Yes
Yes
No
Go to Flowchart A2.
All
terminals?
Yes
Reassign.
Check PRG 10-03-01for
correct Station Assignment.
Assignment
correct?
Perform Multiline Terminal Self Test:
1. Unplug terminal line cord.
2. Hold down 4 and # together and plug in the line cord.
3. Press each terminal key to test tones, LEDs, and key contacts.
4. Return terminal on-line by taking handset off-hook and then
return to on-hook.
Problem
solved?
End.
Reset and test. Replace defective
terminal, and test.
Problem
solved?
Problem
solved?
Problem
solved?
Send terminal
in for repair.
Connect terminal directly
to MDF, and test.
Replace station cable.
Reset and test. Replace
faulty CD-8DLCA.
Send CD-8DLCA in for
repair.
1. Perform Second Initialization, and test.
2. Perform First Initialization, and test.
3. Replace CD-CP00-US, and test using
default program.