UNIVERGE SV8100 Issue 1.0
System Maintenance Manual 3 - 23
SECTION 9 READING SV8100 DIM TRACES
The DIM trace can be partly decoded by the engineer but only NEC Infrontia Japan
can decode the full trace.
This section describes the basic decode to enable the engineer to identify the
extension and trunk port number.
R Extensions
Each extension type has a unique logical port type as shown below.
The port number is identified by the two digits (in hexadecimal) following the
logical port type. The two digits are 00 to ff hexadecimal (00 to 255 in decimal).
(example: keytelephone port 1 will be 0401 as shown below.)
>>>> PORT : 0401H STATUS 0000H => 0002H
R Trunks
Each trunk type has a unique logical port type as shown below.
The port number is identified by the two digits (in hexadecimal) following the
logical port type. The two digits are 00 to ff hexadecimal (00 to 255 in decimal).
(example: ISDN port 17 will be 3411 as shown below.)
>>>> PORT : 3411H STATUS 00D0H => 00B1H
Type Logical ID
Key telephone 04
SLIU 00
S-Point 4c
DECT e9
Type Logical ID
COIU 0c
ISDN 34