UNIVERGE SV8100 Issue 1.0
System Maintenance Manual 2 - 21
Is language
Correct?
A
Is SMDR
port
Correct?
Is the call
type
included in
SMDR?
Yes
Yes
Yes
No
No
No
No
Does the
trunk
provide
SMDR?
Correct the language.
Check PRG 35-01-03
and PRG 80-05-01.
Set port correctly for
Trunks and Dept.
Groups. Check PRG
35-03-01and PRG
35-04-01.
Include the call type.
Check:
PRG 35-01-05~07
PRG 35-02-01~03.
Set Trunk to provide.
Check PRG 14-01-06.
Is call type
included in
the report?
Does
extension
provide
SMDR?
Yes
Yes
Yes
No
Set Extension to
provide.
Check PRG 15-01-03.
Include the call type.
Check
PRG 35-02-08~12.
Yes
End