UNIVERGE SV8100 Issue 1.0
System Maintenance Manual 3 - 11
* PORT STATUS (0401 --> 000f)*
PORT(PHYS) STATUS CALL HOLD
0401h(0001h) : IDLE( 0h) 0000h 0000h
0402h(0101h) : IDLE( 0h) 0000h 0000h
----h(----h) : (----h) ----h ----h no station port is assigned
----h(----h) : (----h) ----h ----h no station port is assigned
----h(----h) : (----h) ----h ----h no station port is assigned
----h(----h) : (----h) ----h ----h no station port is assigned
----h(----h) : (----h) ----h ----h no station port is assigned
----h(----h) : (----h) ----h ----h no station port is assigned
0009h(0002h) : IDLE( 0h) 0000h 0000h
000ah(0102h) : IDLE( 0h) 0000h 0000h
000bh(0202h) : IDLE( 0h) 0000h 0000h
000ch(0302h) : IDLE( 0h) 0000h 0000h
000dh(0402h) : IDLE( 0h) 0000h 0000h
000eh(0502h) : IDLE( 0h) 0000h 0000h
000fh(0602h) : IDLE( 0h) 0000h 0000h
P To display the status of trunk ports 1 through to 10:
status trk 01 0a
R Slot
P To display the information related to the Blade installed into a slot:
slot info nn
Where nn is the slot number 01 to 24 in hexadecimal
(example – an ESIU in slot 1 will show the following):
slot info 01
Slot information)
Slot ID : 1
Status : RUNNING
Logical unit ID : ESIU
Dump down message : Disable
Number of Tx errors : 1
Slot started delay : 2.83sec.
Common unit driver information)
Slot ID : 1
Enter Function DIM Output
slot List the slot commands
available.
SLOT RX Rx simulation
SLOT TX Tx a packet (DSP,64K)
SLOT TXB Tx a packet (128K)
SLOT TXC Tx a packet (LKTS C/0)
SLOT TXK Tx a packet (LKTS KTEL)
SLOT TXS Tx a packet (LKTS STA)
SLOT RESET Reset unit/slot
SLOT INFO Slot/Unit info
SLOT DUMP Dump Tx message
SLOT KEEPALIVE Keep alive control
SLOT IF Slot interface
SLOT WATCHSUBME(only PRI) watch SUBME

Other manuals for NEC Univerge SV8100