NECTA SPA TECHNICAL MANUAL “COLIBRÌ”
Service Manual: Colibrì Edition 02-2002 18 /25
10 - POWDER AND LIQUID DOSE TABLES
FACTORY “DEFAULT” SETTINGS
Selection
Notes Coffee
beans
Instant
Coffee
Water
c.c.
Powder
g
Sugar
g
Notes
Short coffee
Espresso
Time
Quantity
2 sec.
7 g
- -
35 sec.
60 cdv
40
- -
7.5 g
CDV =
Flow-meter
pulses
Long coffee
Time
Quantity
2 sec.
7 g
- -
38 sec.
95 cdv
60
- -
7.5 g
Coffee with milk
Time
Quantity
2 sec.
7 g
- -
38 sec.
60 + 35 cdv
40+25 c.c.
- -
2.0 g of milk
7.5 g
Cappuccino
Time
Quantity
2 sec.
7 g
- -
45 sec.
60 + 72 cdv
40+55
6.0 g of milk
7.5 g
Instant coffee
(Instant version)
Time
Quantity
--
1.3 g 22 sec.
55 cdv
40 c.c.
- -
7.5 g
Instant coffee
Long
Time
Quantity
--
1.3 g 23 sec.
72 cdv
55 c.c.
- -
7.5 g
Instant coffee with
milk
Time
Quantity
--
1.3 g 27 sec.
55 + 35 cdv
40 + 25 c.c.
2.0 g of milk
7.5 g
Cappuccino
Instant
Time
Quantity
--
1.3 g 31 sec.
55 + 72 cdv
40-+55 c.c.
6.0 g of milk
7.5 g
Chocolate
Strong chocolate
Time
Quantity
--
--
32 sec.
116 cdv
90 c.c.
23 g
27 g
--
Instant tea
(Optional)
Time
Quantity
--
--
32 sec.
116 cdv
90 c.c.
12.5 g
--
Milk
Time
Quantity
- -
- -
32 sec.
116 cdv
90 c.c.
8 g
7.5 g
NOTE 1
The water flow in the mixers is approximately 10 c.c. per second and it is given as an indication, as there are
many variables that can affect the accuracy.
The liquid dose is determined by counting the flow-meter pulses (cdv).
Both versions (Instant and Espresso) use an electromechanical vibration pump (with the espresso boiler) for the
water flow; therefore the liquid dose in both versions is measured in cdv (flow-meter pulses).
NOTE 2
To be noted that the number of pulses does not change in a linear manner (i.e. double the amount of water
does not correspond to double the number of pulses), however the counter varies the accuracy according to the
water flow velocity, and namely:
For espresso coffee it is slowed considerably because of the coffee compress reaction that slows down the
water flow, while it is accelerated in the instant drinks selections, since there are no obstructions to the water
flow. Therefore, in the event of changing the default doses set at the factory, some measurements must be
made using graduated measuring containers to check the accuracy of the doses.