EasyManua.ls Logo

NetApp AFF A200 - Page 58

NetApp AFF A200
79 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
If the system-level
diagnostics tests…
Then…
Were completed without
any failures
a.
Clear the status logs:
sldiag device clearstatus
b.
Verify that the log was cleared:
sldiag device status
The following default response is displayed:
SLDIAG: No log messages are present.
c.
Exit Maintenance mode:
halt
The controller displays the LOADER prompt.
d.
Boot the controller from the LOADER prompt:
bye
e. Return the controller to normal operation:
If your controller is in an HA pair, perform a give back:
storage
failover giveback -ofnode replacement_node_name
If you disabled automatic giveback, re-enable it with the
storage failover modify command.
If your controller is in a stand-alone configuration, proceed to the next
step. No action is required.
You have completed system-level diagnostics.
56

Other manuals for NetApp AFF A200

Related product manuals