b. At the LOADER prompt on the target node, check the time and date.
c.
If necessary, modify the date with the
set date mm/dd/yyyy command.
d.
If necessary, set the time, in GMT, using the
set time hh:mm:ss command.
e. Confirm the date and time on the target node.
7.
At the LOADER prompt, enter
bye to reinitialize the PCIe cards and other components and let the node
reboot.
8.
Return the node to normal operation by giving back its storage:
storage failover giveback
-ofnode impaired_node_name
9.
If automatic giveback was disabled, reenable it:
storage failover modify -node local -auto
-giveback true
Step 5: Complete the replacement process
After you replace the part, you can return the failed part to NetApp, as described in the
RMA instructions shipped with the kit. Contact technical support at
NetApp Support, 888-
463-8277 (North America), 00-800-44-638277 (Europe), or +800-800-80-800
(Asia/Pacific) if you need the RMA number or additional help with the replacement
procedure.
1012