• If your system is a stand-alone system you do not need a network connection, but you must perform an
additional reboot when restoring the var file system.
Steps
1. Align the end of the controller module with the opening in the chassis, and then gently push the controller
module halfway into the system.
2. Reinstall the cable management device and recable the system, as needed.
When recabling, remember to reinstall the media converters (SFPs) if they were removed.
3. Insert the USB flash drive into the USB slot on the controller module.
Make sure that you install the USB flash drive in the slot labeled for USB devices, and not in the USB
console port.
4. Push the controller module all the way into the system, making sure that the cam handle clears the USB
flash drive, firmly push the cam handle to finish seating the controller module, push the cam handle to the
closed position, and then tighten the thumbscrew.
The node begins to boot as soon as it is completely installed into the chassis.
5. Interrupt the boot process to stop at the LOADER prompt by pressing Ctrl-C when you see Starting
AUTOBOOT press Ctrl-C to abort….
If you miss this message, press Ctrl-C, select the option to boot to Maintenance mode, and then halt the
node to boot to LOADER.
6. For systems with one controller in the chassis, reconnect the power and turn on the power supplies.
The system begins to boot and stops at the LOADER prompt.
7. Although the environment variables and bootargs are retained, you should check that all required boot
environment variables and bootargs are properly set for your system type and configuration using the
printenv bootarg name command and correct any errors using the setenv variable-name
<value>
command.
a. Check the boot environment variables:
â–ª
bootarg.init.boot_clustered
â–ª
partner-sysid
â–ª
bootarg.init.switchless_cluster.enable
b.
If External Key Manager is enabled, check the bootarg values, listed in the
kenv ASUP output:
â–ª
bootarg.storageencryption.support <value>
â–ª
bootarg.keymanager.support <value>
â–ª
kmip.init.interface <value>
â–ª
kmip.init.ipaddr <value>
â–ª
kmip.init.netmask <value>
â–ª
kmip.init.gateway <value>
c.
If Onboard Key Manager is enabled, check the bootarg values, listed in the kenv ASUP output:
1024

Other manuals for NetApp ASA C Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NetApp ASA C Series and is the answer not in the manual?

NetApp ASA C Series Specifications

General IconGeneral
BrandNetApp
ModelASA C Series
CategoryStorage
LanguageEnglish

Related product manuals