Visually inspect the DIMM to verify that it is evenly aligned and fully inserted into the slot.
8. Repeat these steps for the remaining DIMMs.
9. Locate the NVMEM battery plug socket, and then squeeze the clip on the face of the battery cable plug to
insert it into the socket.
Make sure that the plug locks down onto the controller module.
Step 5: Move the caching module
To move a caching module referred to as the M.2 PCIe card on the label on your
controller, locate and move it from the old controller into the replacement controller and
follow the specific sequence of steps.
You must have the new controller module ready so that you can move the caching module directly from the old
controller module to the corresponding slot in the new one. All other components in the storage system must
be functioning properly; if not, you must contact technical support.
Steps
1. Locate the caching module at the rear of the controller module and remove it.
a. Press the release tab.
b. Remove the heatsink.
1056