4.
View the status of the test by entering the following command:
sldiag device status
Your storage system provides the following output while the tests are still running:
There are still test(s) being processed.
After all the tests are complete, the following response appears by default:
*> <SLDIAG:_ALL_TESTS_COMPLETED>
5.
Identify the cause of the system sluggishness by entering the following command:
sldiag device
status -long -state failed
The following example shows how the full status of the failures is displayed in a test run without the
appropriate hardware:
*> **sldiag device status -long -state failed**
TEST START ------------------------------------------
DEVTYPE: nvram_ib
NAME: external loopback test
START DATE: Sat Jan 3 23:10:55 GMT 2009
STATUS: Completed
ib3a: could not set loopback mode, test failed
END DATE: Sat Jan 3 23:11:04 GMT 2009
LOOP: 1/1
TEST END --------------------------------------------
TEST START ------------------------------------------
DEVTYPE: fcal
NAME: Fcal Loopback Test
START DATE: Sat Jan 3 23:10:56 GMT 2009
STATUS: Completed
Starting test on Fcal Adapter: 0b
Started gathering adapter info.
Adapter get adapter info OK
Adapter fc_data_link_rate: 1Gib
Adapter name: QLogic 2532
Adapter firmware rev: 4.5.2
Adapter hardware rev: 2
Started adapter get WWN string test.
1448

Other manuals for NetApp ASA C Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NetApp ASA C Series and is the answer not in the manual?

NetApp ASA C Series Specifications

General IconGeneral
BrandNetApp
ModelASA C Series
CategoryStorage
LanguageEnglish

Related product manuals