the storage aggregate delete -aggregate aggregate_name command.
• If your system shipped in a system cabinet, you need a Phillips screwdriver to remove the screws securing
the shelf to the cabinet rear uprights.
About this task
• If you are hot-removing more than one shelf, you remove one shelf at a time.
• Best practice: The best practice is to remove drive ownership after you remove the aggregates from the
drives in the shelf you are removing.
Removing ownership information from a spare drive allows the drive to be properly integrated into another
node (as needed).
The procedure for removing ownership from drives can be found in the disks and aggregates content:
Disks and aggregates overview
The procedure requires you to disable automatic drive assignment. You reenable automatic
drive assignment at the end of this procedure (after you have hot-removed the shelf).
• If needed, you can turn on the shelf’s location (blue) LEDs to aid in physically locating the affected shelf:
storage shelf location-led modify -shelf-name shelf_name -led-status on
If you do not know the shelf_name of the affected shelf, run the storage shelf show command.
A shelf has three location LEDs: one on the operator display panel and one on each NSM module.
Location LEDs remain illuminated for 30 minutes. You can turn them off by entering the same command,
but using the off option.
• After disconnecting a shelf from non-dedicated RoCE capable ports (on board the controllers, on RoCE
capable PCIe cards, a combination of both, or on I/O modules), you have the option of reconfiguring these
ports for networking use.
If your HA pair is running a version of ONTAP 9.6, you need to reboot the controllers one at
a time.
If your HA pair is running ONTAP 9.7 or later, you do not need to reboot the controllers,
unless one or both controllers are in maintenance mode. This procedure assumes that
neither controller is in maintenance mode.
Steps
1. Properly ground yourself.
2. Verify that the drives in the shelf you are removing have no aggregates (are spares) and that ownership is
removed:
a.
Enter the following command to list all of the drives in the shelf that you are removing:
storage disk
show -shelf shelf_number
You can enter the command on either controller module.
b. Check the output to verify that there are no aggregates on the drives.
1527

Other manuals for NetApp ASA C Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NetApp ASA C Series and is the answer not in the manual?

NetApp ASA C Series Specifications

General IconGeneral
BrandNetApp
ModelASA C Series
CategoryStorage
LanguageEnglish

Related product manuals