Page #168 background imageLoading...
Page #168 background image
If the impaired node is
displaying…
Then…
System prompt or password
prompt (enter system password)
Take over or halt the impaired node:
• For an HA pair, take over the impaired node from the healthy
node:
storage failover takeover -ofnode
impaired_node_name
When the impaired node shows Waiting for giveback…, press
Ctrl-C, and then respond
y.
4. If the impaired node is part of an HA pair, disable automatic giveback from the console of the healthy node:
storage failover modify -node local -auto-giveback false
5. Take the impaired node to the LOADER prompt:
If the impaired node is
displaying…
Then…
The LOADER prompt Go to the next step.
Waiting for giveback…
Press Ctrl-C, and then respond y when prompted.
System prompt or password
prompt (enter system password)
Take over or halt the impaired node:
• For an HA pair, take over the impaired node from the healthy
node:
storage failover takeover -ofnode
impaired_node_name
When the impaired node shows Waiting for giveback…, press
Ctrl-C, and then respond
y.
•
For a stand-alone system:
system node halt
impaired_node_name
6. If the system has only one controller module in the chassis, turn off the power supplies, and then unplug
the impaired node’s power cords from the power source.
Option 2: Controller is in a MetroCluster
Do not use this procedure if your system is in a two-node MetroCluster configuration.
To shut down the impaired node, you must determine the status of the node and, if necessary, take over the
node so that the healthy node continues to serve data from the impaired node storage.
• If you have a cluster with more than two nodes, it must be in quorum. If the cluster is not in quorum or a
healthy node shows false for eligibility and health, you must correct the issue before shutting down the
impaired node; see the Administration overview with the CLI.
• If you have a MetroCluster configuration, you must have confirmed that the MetroCluster Configuration
165

Other manuals for NetApp ASA C Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NetApp ASA C Series and is the answer not in the manual?

NetApp ASA C Series Specifications

General IconGeneral
BrandNetApp
ModelASA C Series
CategoryStorage
LanguageEnglish

Related product manuals