a.
Use the
security key-manager key show -detail to see a detailed view of all keys stored in
the onboard key manager.
b.
Use the
security key-manager key show -detail command and verify that the Restored
column = yes for all authentication keys.
If the
Restored column = anything other than yes, use the security key-manager setup
-node Repaired(Target)node
command to restore the Onboard Key Management settings.
Rerun the
security key-manager key show -detail command to verify Restored column =
yes for all authentication keys.
12. Connect the console cable to the partner node.
13.
Give back the node using the
storage failover giveback -fromnode local command.
14.
Restore automatic giveback if you disabled it by using the
storage failover modify -node local
-auto-giveback true
command.
Option 3: Restore NSE/NVE on systems running ONTAP 9.6 and later
Steps
1. Connect the console cable to the target node.
2.
Use the
boot_ontap command at the LOADER prompt to boot the node.
3. Check the console output:
If the console
displays…
Then…
The login prompt Go to Step 7.
Waiting for giveback… a. Log into the partner node.
b.
Confirm the target node is ready for giveback with the
storage
failover show
command.
4.
Move the console cable to the partner node and give back the target node storage using the
storage
failover giveback -fromnode local -only-cfo-aggregates true local
command.
â—¦ If the command fails because of a failed disk, physically dis-engage the failed disk, but leave the disk in
the slot until a replacement is received.
â—¦ If the command fails because of an open CIFS sessions, check with customer how to close out CIFS
sessions.
Terminating CIFS can cause loss of data.
â—¦ If the command fails because the partner "not ready", wait 5 minutes for the NVMEMs to synchronize.
â—¦ If the command fails because of an NDMP, SnapMirror, or SnapVault process, disable the process. See
the appropriate Documentation Center for more information.
5.
Wait 3 minutes and check the failover status with the
storage failover show command.
6.
At the clustershell prompt, enter the
net int show -is-home false command to list the logical
interfaces that are not on their home node and port.
20

Other manuals for NetApp ASA C Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NetApp ASA C Series and is the answer not in the manual?

NetApp ASA C Series Specifications

General IconGeneral
BrandNetApp
ModelASA C Series
CategoryStorage
LanguageEnglish

Related product manuals