Only connect the power cable to the power supply. Do not connect the power cable to a
power source at this time.
Step 2: Remove the controller module
Remove the controller module or modules from the old chassis.
Steps
1. Loosen the hook and loop strap binding the cables to the cable management device, and then unplug the
system cables and SFPs (if needed) from the controller module, keeping track of where the cables were
connected.
Leave the cables in the cable management device so that when you reinstall the cable management
device, the cables are organized.
2. Remove and set aside the cable management devices from the left and right sides of the controller module.
3. Squeeze the latch on the cam handle until it releases, open the cam handle fully to release the controller
module from the midplane, and then, using two hands, pull the controller module out of the chassis.
4. Set the controller module aside in a safe place, and repeat these steps if you have another controller
module in the chassis.
24