EasyManuals Logo

NetApp ASA C Series System Documentation

NetApp ASA C Series
1672 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #59 background imageLoading...
Page #59 background image
appears.
3.
Run diagnostics on the system memory:
sldiag device run -dev mem
4.
Verify that no hardware problems resulted from the replacement of the DIMMs:
sldiag device status
-dev mem -long -state failed
System-level diagnostics returns you to the prompt if there are no test failures, or lists the full status of
failures resulting from testing the component.
5. Proceed based on the result of the preceding step:
If the system-level
diagnostics tests…
Then…
Were completed without
any failures
a.
Clear the status logs:
sldiag device clearstatus
b.
Verify that the log was cleared:
sldiag device status
The following default response is displayed:
SLDIAG: No log messages are present.
c.
Exit Maintenance mode:
halt
The node displays the LOADER prompt.
d.
Boot the node from the LOADER prompt:
bye
e. Return the node to normal operation:
If your node is in an HA pair, perform a give back:
storage failover
giveback -ofnode replacement_node_name
Note: If you disabled automatic giveback, re-enable it with the storage
failover modify
command.
If your node is in a stand-alone configuration, proceed to the next step. No
action is required.
You have completed system-level diagnostics.
56

Other manuals for NetApp ASA C Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NetApp ASA C Series and is the answer not in the manual?

NetApp ASA C Series Specifications

General IconGeneral
BrandNetApp
ModelASA C Series
CategoryStorage
LanguageEnglish

Related product manuals