a. Point your browser to the node management IP address.
The format for the address is https://x.x.x.x.
b. Configure the system using the data you collected in the NetApp ONTAP Configuration guide.
ONTAP Configuration Guide
5. Verify the health of your system by running Config Advisor.
6. After you have completed the initial configuration, go to the
ONTAP & ONTAP System Manager
Documentation Resources
page for information about configuring additional features in ONTAP.
Maintain
Boot media
Replace the boot media - AFF A800
• You must replace the failed component with a replacement FRU component you received from your
provider.
• It is important that you apply the commands in these steps on the correct node:
â—¦ The impaired node is the node on which you are performing maintenance.
â—¦ The healthy node is the HA partner of the impaired node.
Check onboard encryption keys as needed - AFF A800
Prior to shutting down the impaired node and checking the status of the onboard
encryption keys, you must check the status of the impaired node, disable automatic
giveback, and check what version of ONTAP the system is running.
If you have a cluster with more than two nodes, it must be in quorum. If the cluster is not in quorum or a healthy
node shows false for eligibility and health, you must correct the issue before shutting down the impaired node;
see the
NetApp Encryption overview with the CLI.
Steps
1. Check the status of the impaired node:
â—¦
If the impaired node is at the login prompt, log in as
admin.
â—¦
If the impaired node is at the LOADER prompt and is part of HA configuration, log in as
admin on the
healthy node.
â—¦ If the impaired node is in a standalone configuration and at LOADER prompt, contact NetApp Support.
mysupport.netapp.com
2. If AutoSupport is enabled, suppress automatic case creation by invoking an AutoSupport message:
system node autosupport invoke -node * -type all -message
MAINT=number_of_hours_downh
The following AutoSupport message suppresses automatic case creation for two hours: cluster1:*>
system node autosupport invoke -node * -type all -message MAINT=2h
846

Other manuals for NetApp ASA C Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NetApp ASA C Series and is the answer not in the manual?

NetApp ASA C Series Specifications

General IconGeneral
BrandNetApp
ModelASA C Series
CategoryStorage
LanguageEnglish

Related product manuals