If the management network has
DHCP…
Then…
Not configured a. Open a console session using PuTTY, a terminal server, or the
equivalent for your environment.
Check your laptop or console’s online help if you do
not know how to configure PuTTY.
b. Enter the management IP address when prompted by the script.
5. Using System Manager on your laptop or console, configure your cluster:
a. Point your browser to the node management IP address.
The format for the address is https://x.x.x.x.
b. Configure the system using the data you collected in the
NetApp ONTAP Configuration Guide.
6. Verify the health of your system by running Config Advisor.
7. After you have completed the initial configuration, go to the ONTAP & ONTAP System Manager
Documentation Resources
page for information about configuring additional features in ONTAP.
The default port configuration for Unified configuration systems is CNA mode; if connecting
to an FC host network, you have to modify the ports for FC mode.
Maintain
Boot media
Replace the boot media - AFF C190
The boot media stores a primary and secondary set of system (boot image) files that the
system uses when it boots. Depending on your network configuration, you can perform
either a nondisruptive or disruptive replacement.
You must have a USB flash drive, formatted to FAT32, with the appropriate amount of storage to hold the
image_xxx.tgz.
• The nondisruptive and disruptive methods for replacing a boot media both require you to restore the var file
system:
â—¦ For nondisruptive replacement, the HA pair must be connected to a network to restore the var file
system.
â—¦ For disruptive replacement, you do not need a network connection to restore the var file system, but
the process requires two reboots.
• You must replace the failed component with a replacement FRU component you received from your
provider.
• It is important that you apply the commands in these steps on the correct node:
953

Other manuals for NetApp ASA C Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NetApp ASA C Series and is the answer not in the manual?

NetApp ASA C Series Specifications

General IconGeneral
BrandNetApp
ModelASA C Series
CategoryStorage
LanguageEnglish

Related product manuals