nic is a network interface card.
â—¦
nvram is nonvolatile RAM.
â—¦
nvmem is a hybrid of NVRAM and system memory.
â—¦
sas is a Serial Attached SCSI device not connected to a disk shelf.
4. Run diagnostics as desired.
If you want to run diagnostic
tests on…
Then…
Individual components a. Clear the status logs:
sldiag device clearstatus
b. Display the available tests for the selected devices:
sldiag device show -dev dev_name
dev_name
can be any one of the ports and devices identified in
the preceding step.
c. Examine the output and, if applicable, select only the tests that
you want to run:
sldiag device modify -dev dev_name -selection
only
-selection only disables all other tests that you do not want to run
for the device.
d. Run the selected tests:
sldiag device run -dev dev_name
After the test is complete, the following message is displayed:
*> <SLDIAG:_ALL_TESTS_COMPLETED>
e. Verify that no tests failed:
sldiag device status -dev dev_name -long -state
failed
System-level diagnostics returns you to the prompt if there are no
test failures, or lists the full status of failures resulting from testing
the component.
984

Other manuals for NetApp ASA C Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NetApp ASA C Series and is the answer not in the manual?

NetApp ASA C Series Specifications

General IconGeneral
BrandNetApp
ModelASA C Series
CategoryStorage
LanguageEnglish

Related product manuals