EasyManuals Logo

NetApp DS224C User Manual

NetApp DS224C
58 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #16 background imageLoading...
Page #16 background image
Removing the cable chains
Left and right cable chains for each drive drawer in the DS460C drive shelf allow the
drawers to slide in and out. Before you can remove a drive drawer, you must remove both
cable chains.
Before you begin
You have stopped host I/O activity and powered off the shelf.
You have obtained the following items:
Antistatic protection
Possible hardware damage: To prevent electrostatic discharge damage to the shelf,
use proper antistatic protection when handling shelf components.
Flashlight
About this task
Each drive drawer has left and right cable chains. The metal ends on the cable chains slide into corresponding
vertical and horizontal brackets inside the enclosure, as follows:
The left and right vertical brackets connect the cable chain to the enclosure’s midplane.
The left and right horizontal brackets connect the cable chain to the individual drawer.
Steps
1. Put on antistatic protection.
2. From the rear of the drive shelf, remove the right fan module, as follows:
a. Press the orange tab to release the fan module handle.
The figure shows the handle for the fan module extended and released from the orange tab on the left.
14

Other manuals for NetApp DS224C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NetApp DS224C and is the answer not in the manual?

NetApp DS224C Specifications

General IconGeneral
Form Factor2U
Drive Bays24
Drive Type2.5-inch SAS
Maximum Raw Capacity368 TB
Connectivity12 Gbps SAS
Power SupplyRedundant power supplies
CoolingRedundant fans
Storage TypeHDD and SSD
CompatibilityNetApp FAS and AFF systems