EasyManuals Logo

NetApp DS4243 User Manual

NetApp DS4243
74 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #26 background imageLoading...
Page #26 background image
The following output for the storage disk show -shelf3 command shows that disk
drives on the disk shelf being removed (disk shelf 3) have the ownership removed;
therefore, unassigned appears in the Container Type column. Two disk drives are
failed; therefore, broken appears in the Container Type column:
cluster::> storage disk show -shelf 3
Usable Disk Container Container
Disk Size Shelf Bay Type Type Name Owner
-------- -------- ----- --- ------ ----------- ---------- ---------
...
1.3.4 - 3 4 SAS unassigned - -
1.3.5 - 3 5 SAS unassigned - -
1.3.6 - 3 6 SAS broken - -
1.3.7 - 3 7 SAS broken - -
...
4.
Turn on the LEDs for each disk shelf you are removing so that the disk shelves are physically
identifiable, by entering the following command for each disk shelf you are removing:
storage shelf identify adapter_name.shelfshelf_ID on
You must be in advanced privilege level to enter this command. You can enter the command
from the console of either controller. For clustered systems, enter the command from the
nodeshell.
All LEDs on the front and back of the specified disk shelves flash. LEDs continue to flash for
up to five minutes.
Note: You need to be certain of which disk shelves you are removing so that you can
correctly recable path A and path B later in this procedure. Even if you are removing an
entire stack of disk shelves, it is recommended that you use this command.
To physically identify disk shelf 3, you enter storage shelf identify 0b.shelf3 on.
5. If you are removing an entire stack of disk shelves, complete the following substeps;
otherwise, go to the next step:
a. Remove all SAS cables on path A and path B.
This includes controller-to-shelf cables and shelf-to-shelf cables for all disk shelves in the
stack you are removing.
b. If you are using ACP, recable the applicable ACP stack connections to bypass the stack
you are removing:
To reference illustrations of ACP cabling for multipath HA systems, see the
SAS and
ACP Cabling Guide for DS4243, DS2246, DS4486, and DS4246 Disk Shelves
on the
NetApp Support Site at
mysupport.netapp.com
.
DS4243, DS2246, DS4486, and DS4246 Installation and Service Guide 26
Hot-removing disk shelves or stacks in systems running Data ONTAP 8.2.1 or later

Table of Contents

Other manuals for NetApp DS4243

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NetApp DS4243 and is the answer not in the manual?

NetApp DS4243 Specifications

General IconGeneral
BrandNetApp
ModelDS4243
CategoryStorage
LanguageEnglish

Related product manuals