3. Click Browse, and then select the feature pack you want to apply.
4.
Type
CHANGE in the field.
5. Click Change.
The feature pack migration begins. Both controllers automatically reboot twice to allow the new feature
pack to take effect. The storage array returns to a responsive state after the reboot is complete.
6. Confirm the host ports have the protocol you expect.
a. From SANtricity System Manager, select Hardware.
b. Click Show back of shelf.
c. Select the graphic for either Controller A or Controller B.
d. Select View settings from the context menu.
e. Select the Host Interfaces tab.
f. Click Show more settings.
g. Review the details shown for the baseboard ports and the HIC ports (labeled “slot 1”), and confirm that
each type of port has the protocol you expect.
What’s next?
Go to
Complete host protocol conversion.
Complete host protocol conversion for E2800
After converting the protocol of the host ports, you must perform additional steps before
you can use the new protocol.
The steps depend on the starting and ending protocols of the baseboard host ports and the HIC ports.
Complete FC to iSCSI conversion
If you converted all host ports from FC to iSCSI, you must configure iSCSI networking.
Steps
1. Configure the switches.
You should configure the switches used to transport iSCSI traffic according to the vendor’s
recommendations for iSCSI. These recommendations might include both configuration directives as well as
259