(1) Handle to pull the fan canister out.
4. Slide the replacement fan canister all the way into the shelf, and then move the fan canister handle until it
latches with the orange tab.
Step 3: Complete fan canister replacement
Confirm that the new fan canister is working correctly, gather support data, and resume normal operations.
Steps
1. Check the amber Attention LED on the new fan canister.
After you replace the fan canister, the Attention LED stays on (solid amber) while the
firmware checks that the fan canister was installed correctly. The LED goes off after this
process is complete.
2. From the Recovery Guru in SANtricity System Manager, select Recheck to ensure the problem has been
resolved.
3. If a failed fan canister is still being reported, repeat the steps in
Step 2: Remove failed fan canister and
install new one
. If the problem persists, contact technical support.
4. Remove the antistatic protection.
5. Collect support data for your storage array using SANtricity System Manager.
If a problem occurs during this procedure, you can use the saved file to troubleshoot the issue. The system
will save inventory, status, and performance data about your storage array in a single file.