3.
Resynchronize the data aggregates by running the
metrocluster heal -phase aggregates
command from the surviving cluster.
controller_A_1::> metrocluster heal -phase aggregates
[Job 130] Job succeeded: Heal Aggregates is successful.
If the healing is vetoed, you have the option of reissuing the metrocluster heal command with the
-override-vetoes parameter. If you use this optional parameter, the system overrides any soft vetoes that
prevent the healing operation.
4. Verify that the operation has been completed by using the metrocluster operation show command.
controller_A_1::> metrocluster operation show
Ê Operation: heal-aggregates
Ê State: successful
Start Time: 7/25/2016 18:45:55
Ê End Time: 7/25/2016 18:45:56
Ê Errors: -
5.
Check the state of the aggregates by using the
storage aggregate show command.
controller_A_1::> storage aggregate show
Aggregate Size Available Used% State #Vols Nodes RAID
Status
--------- -------- --------- ----- ------- ------ ----------------
------------
...
aggr_b2 227.1GB 227.1GB 0% online 0 mcc1-a2
raid_dp, mirrored, normal...
6.
Heal the root aggregates by using the
metrocluster heal -phase root-aggregates command.
mcc1A::> metrocluster heal -phase root-aggregates
[Job 137] Job succeeded: Heal Root Aggregates is successful
If the healing is vetoed, you have the option of reissuing the metrocluster heal command with the
-override-vetoes parameter. If you use this optional parameter, the system overrides any soft vetoes that
prevent the healing operation.
7.
Verify that the heal operation is complete by using the
metrocluster operation show command on
the destination cluster:
10

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NetApp FAS8200 and is the answer not in the manual?

NetApp FAS8200 Specifications

General IconGeneral
ControllerDual
Maximum Drives1440
NVMe Flash CacheYes
Form Factor4U
Operating SystemONTAP
High AvailabilityYes
NVRAM32GB
Maximum Flash Cache12TB
Connectivity16Gb FC
Maximum Memory256GB
ProtocolsNFS, CIFS, iSCSI, FC
ProcessorIntel Xeon
Drive Types SupportedSAS, SSD
Data Protection FeaturesRAID-DP, RAID-TEC, SnapMirror, SnapVault

Related product manuals