ReadyNAS 2100 User Manual
Setting Up and Managing Your ReadyNAS 2100 2-29
v1.0, May 2009
1. Select the SNMP tab to display the SNMP settings.
2. Select the Enable SNMP service check box. You can leave the Community field set to
public, or specify a private name if you have opted for a more segregated monitoring scheme.
3. Enter a host name or an IP address in the Trap destination field. This is where all trap
messages will be sent. The following system events generate a trap:
Abnormal power voltage
Abnormal board enclosure temperature
•Fan failure
UPS connected
UPS detected power failure
RAID disk sync started and finished
RAID disk added, removed, and failure
Snapshot invalidated
4. If you wish to limit SNMP access to only a secure list of hosts, specify the hosts in the Hosts
allowed access field.
5. Click Apply to save your settings.
When you have saved the SNMP settings on the ReadyNAS 2100, you can import the NETGEAR
SNMP MIB to your SNMP client application. The NETGEAR MIB can be obtained from the
included Installation CD or downloaded from the NETGEAR Support site at
http://www.netgear.com/support.
SMTP
The ReadyNAS 2100 device has a built-in e-mail message transfer agent (MTA) that is set up to
send alert e-mail messages from the device. Some corporate environments, however, might have a
firewall that blocks untrusted MTAs from sending out messages.