Power Supply

Requires 48V phantom power (P48, IEC 61938) supplying at least 3.2 mA per channel.

Pin Assignment

Balanced, transformerless output via 3-pin XLR. Pin 1: OV/ground, Pin 2: Mod (+), Pin 3: Mod (-).

Technical Specifications

Sensitivity

13 mV/Pa = -38 dBV ± 1 dB.

Signal-to-Noise Ratio

71 dB (CCIR) / 82 dB (A-weighted).

Max. SPL

110 dB (0.5% THD) / 129 dB (5% THD).

Supply Voltage

48 V ± 4 V.

Frequency Responses and Polar Pattern

Neumann TLM 49 Specifications

General IconGeneral
Transducer TypeCondenser
Acoustical operating principlePressure gradient transducer
Polar PatternCardioid
Frequency Response20 Hz - 20 kHz
Sensitivity13 mV/Pa
Impedance50 ohms
Rated load impedance1000 ohms
Supply voltage48 V ± 4 V
Current consumption3.2 mA
Connecting connectorXLR 3F
Weight825 g
Maximum SPL110 dB (for THD = 0.5%)
Power Supply48 V Phantom power (P48)