EasyManuals Logo

NEURON THC User Manual

NEURON THC
53 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #40 background imageLoading...
Page #40 background image
USER MANUAL
10. Move the torch down as it possible (buttons UP/DOWN). Copy the value of the torch
position and put it in the “Slide Length” box (Soft Limit function).
11. Set up the maximum values of the acceleration and velocity of the torch moving as your
system allowed (avoid lost steps for steppers motors). Usually Acceleration in cut is
equivalent acceleration.
12. Set up manual and IHS velocity.
13. Set up “Safe Jog Height” in percent’s ofSlide Length” value. “Safe Jog Height” is the
distance from home position where the fast jog is allowed. Below this point the torch will
move with IHS velocity only.
14. Tune up the Float Head:
Put the flat plate on the cutting table. Thickness not less 3 mm. Open the settings
window by clicking “NEURON” button.
Move to the tab «Engine Settings» and set the check box «Start Setup» in the field
“Float Head correction”.
Set “Start Setup” checkbox. Controller will start Initial Height Sensing procedure.
When the IHS will be completed the torch will be moved up on the 4mm for metric
system or 0.2 in for inches system under surface of the plate.
Check the distance between the surface of the plate and torch nozzle. If it’s not
4mm (0.2 in.) (check it for example by standard drill) correct it by rotating
multiturn encoder on the operator panel.
For finish uncheck “Start Setup” checkbox.
15. Connect plasma interface PCB with plasma unit according the schematic in the user
manual.
16. Calibrate Arc voltage converter module by calculating correction value.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NEURON THC and is the answer not in the manual?

NEURON THC Specifications

General IconGeneral
BrandNEURON
ModelTHC
CategoryController
LanguageEnglish