BEFORE FIRING HEATER
Please note that some parts are shipped inside the appliance. Remove and assemble as required. If necessary, slide
the firebricks back to the rear so that no gaps remain between them.
CLEARANCES TO COMBUSTIBLES FLOOR PROTECTION
Refer to the certification label on the appliance and the following diagrams for the appropriate model being installed.
WARNING: Install on durable non-combustible and non-heat conducting pad, equivalent to asbestos mill-board of at
least 3/8” (10 mm) minimum thickness, which extends at least 8” (205 mm) from the unit on all sides, and 18 (455 mm)
from the firedoor end. Alternatively install in accordance with provisions of NFPA 211 (USA) or CAN/CSA-B365
(Canada). Do not obstruct the space beneath the stove.
WARNING: Maintain minimum specified clearances to combustible materials. Do not place fuel (wood) within specified
clearances or within space required for charging and/or ash removal.
CLEARANCE TO COMBUSTIBLES, WALLS AND CEILING - NS220E Newmac Status EPA